Weld Defects, Testing, and Inspection
What You'll Learn
- 1Classify weld defects as fusion, gas, geometry, or cracking faults
- 2Match each defect family to a nondestructive method and its sensitivity
- 3Read AWS D1.1 and ISO 5817 acceptance limits numerically
- 4Judge a planar defect with a fracture mechanics acceptance calculation
A cracked weld that passed visual inspection is the most expensive failure in fabrication, because the crack grows under load and the repair stops production weeks later. Inspection is not one technique but a matching problem: cracks need magnetic or penetrant testing, voids need radiography, and lack of fusion needs ultrasonics. This lesson maps each defect family to a method, gives the sensitivity of each, and shows how acceptance codes turn a measurement into a decision.
Theory and Foundations
Weld defects fall into four families. Gas porosity appears as spherical voids from hydrogen in the electrode, damp flux, or lost gas. Fusion defects come from low heat input or a wrong work angle and hide at the root where they are hardest to see. Geometry defects, undercut, overlap, excess reinforcement, and misalignment, are surface stress raisers. Cracking divides into solidification cracks that form during freezing and hydrogen cracks that follow hours later, often overnight.
Each is detected by one of three physical interactions: a surface-breaking discontinuity that holds liquid penetrant or disturbs a magnetic field, a volumetric discontinuity that absorbs or scatters radiation or reflects sound, and a geometry deviation a gauge can measure. Selection turns on orientation and depth, because a method excellent for one orientation is blind to another.
Probability of detection describes a method quantitatively: for a flaw of size , the probability that the method reports it is modelled as
where is the flaw size found half the time and the curve steepness, usually 2 to 4 for a well-controlled ultrasonic procedure. Reporting at the 90 percent point, written , is what a procedure qualification demonstrates, and that is the number that belongs in the inspection plan.
Radiographic sensitivity is set by the image quality indicator on the film, and the wire diameter that must be visible is a fraction of the wall thickness:
with near 0.02 for level two and 0.01 for level one, so on 20 mm wall a level two film must show a wire of about 0.4 mm diameter. Ultrasonic sensitivity is set on a distance-amplitude curve from side-drilled holes, and a planar flaw is reported when its echo rises above 50 percent of that curve.
Geometry defects are judged by notch mechanics: an undercut of depth and root radius raises local stress by a factor close to the short-notch relation
so a shallow, sharp undercut is more damaging than its depth suggests, and times nominal stress gives the local peak stress the material must survive without yielding.
Planar defects are judged by fracture mechanics: a surface-breaking flaw of depth under nominal stress has a stress intensity factor
with a geometry factor near 1.12 for a surface crack in a semi-infinite plate. Acceptance follows from the plain statement that must stay below a fraction of the fracture toughness:
where is the safety factor, normally 2 for a welded joint. Because allowable size falls with the square of stress, a flaw tolerated at low stress becomes critical at high stress, which is why codes reject cracks outright instead of grading them.
Finally, an inspection plan has its own statistics: if a single sample detects a defective weld with probability , the chance that all samples miss it entirely is
which is why the sampling rate rises with joint consequence class instead of staying at one coupon per weld.
Key Formulas
Radiographic and ultrasonic thresholds complete the set: a film is acceptable when the required wire shows, and a scan when no indication exceeds the reference level for the applicable code section,
A common screening threshold for planar indications, with anything above it sized and dispositioned individually.
Worked Examples
| Method | Orientation detected | Depth capability | Practical sensitivity | Relative cost |
|---|---|---|---|---|
| Visual (VT) | surface-breaking | surface only | features about 0.5 mm | 1 |
| Magnetic particle (MT) | surface and near-surface | to about 1 mm | fine crack about 0.05 mm wide | 2 |
| Dye penetrant (PT) | surface-breaking open to surface | surface only | about 0.01 mm wide | 2 |
| Radiography (RT) | volumetric, any orientation | through wall | wire at 2 percent of thickness | 4 |
| Ultrasonics (UT) | planar, best perpendicular to beam | full wall, 5 mm dead zone | about 2 mm flaw, sized plus or minus 1 mm | 3 |
| Phased array UT | planar, angular sector scan | full wall | about 1 mm, sized continuously | 5 |
Real-World Examples
- Pipeline girth weld - Each weld is radiographed to API 1104 with a 10 percent wire indicator on the film, and repair rate is tracked per welder.
- Pressure vessel shell - A 40 mm seam receives both ultrasonic and radiographic examination, with heat-affected zone hardness capped at 250 HV to confirm the preheat.
- Structural girder - Butt welds receive visual plus magnetic particle inspection, with undercut held below 0.8 mm and rejected below 0.3 mm when the joint is fatigue loaded.
- Stainless tank - A 316L tank is dye penetrant tested to ASTM E165 after passivation to confirm no heat tint cracking survived cleaning.
đĄTest After Repair, Always
Common Mistakes
Using penetrant testing on cast iron
Fix: Switch to magnetic particle, since cast iron holds dye that masks it.
Accepting small undercut without checking the loading
Fix: Look up the limit for the joint class, because fatigue joints often need below 0.3 mm, not 0.8 mm.
Updating a WPS without a new PQR
Fix: Requalify whenever heat input, filler, or preheat moves outside the proven range.
Key Takeaways
- Method choice follows orientation: cracks to MT or PT, voids to RT, planar flaws to UT
- Radiographic sensitivity is a wire at about 2 percent of wall thickness
- Undercut notch factor is one plus two times the square root of depth over radius
- Allowable flaw size falls with the square of stress, so codes reject cracks outright
Frequently Asked Questions
Can radiography detect lack of fusion?
Only when the flaw is oriented to interrupt the beam, so ultrasonics is specified for critical joints where lack of fusion matters. A tight line running parallel to the beam casts almost no shadow on film.
How long does a welder qualification remain valid?
Under AWS D1.1 the continuity requirement is six months: welding must occur within that period or the qualification lapses and the welder must retest in the affected process and position.
Which test finds defects that lie under the surface?
Magnetic particle and ultrasonics both reach subsurface, but only ultrasonics measures depth and sizes internal planar flaws, which is why it supports fracture mechanics acceptance.
Interview Questions
Q1: How do you choose between RT and UT for a critical butt weld?
RT is best for volumetric and root defects, UT for planar lack of fusion, and many pressure codes require both.
Q2: What makes an NDT report defensible?
Traceable procedures to ASTM or ASME, calibrated blocks, qualified Level II personnel, and the acceptance code section on the report.