Vibration Fundamentals: Free and Forced Response, Resonance
What You'll Learn
- 1Build and solve the single-degree-of-freedom equation of motion
- 2Extract natural frequency and damping ratio from free-decay data
- 3Predict resonant amplitude and isolation performance from frequency ratio
- 4Balance rotors to a specified grade and read 1x spectral lines
- 5Choose between detuning, damping, isolation, and absorption
Vibration is oscillatory motion about an equilibrium position, and in machinery it is rarely harmless: it makes noise, shortens fatigue life at welds and fillets, corrupts machine-tool geometry, and is uncomfortable for people. Every system has natural frequencies set by its mass and stiffness distribution, and every running machine supplies excitation at running speed, at harmonics of it, and at blade or tooth passing frequencies. When an excitation line sits on a structural or rotor natural frequency, the response amplifies and a modest force becomes a large displacement. The design response has four levers, and only four: move the natural frequency away from the excitation (detune), add damping to cap the peak, interrupt the transmission path (isolate), or add a tuned absorber that reacts the force locally. This lesson develops the single-degree-of-freedom model far enough to make those four levers quantitative, then adds rotordynamics, where unbalance force grows with the square of speed, and shows how spectra separate rotor problems from structural ones.
Modeling: Mass, Stiffness, and Damping
A single-degree-of-freedom (SDOF) system is the smallest model that still contains resonance: one inertia , one spring , one damper , and one coordinate . Newton's second law on the mass gives the governing equation, and any linear vibration problem in this lesson reduces to it:
The right-hand side is zero for free vibration and harmonic for forced vibration. Units follow SI strictly: in kg, in N/m, in N s/m, and in m and N, in rad/s. Two derived quantities organize everything that follows: the undamped natural frequency and the damping ratio.
The critical damping coefficient is the value that just barely stops oscillation on release. Equivalent stiffness follows the same series and parallel rules as resistors, but inverted for series: springs in parallel add, springs in series combine as the inverse sum of inverses, and a cantilever's tip stiffness often replaces a coil constant in structural models.
| Quantity | Symbol | Unit | Typical machine value |
|---|---|---|---|
| Natural frequency | Hz | 2 to 200 Hz for mounts and frames | |
| Angular natural frequency | rad/s | ||
| Damping ratio | dimensionless | 0.01 steel weldment, 0.05 to 0.2 rubber | |
| Static deflection under gravity | m | , 25 mm at 3 Hz | |
| Harmonic velocity | m/s | for amplitude | |
| Harmonic acceleration | m/s squared | , the load that breaks brackets |
Note the last row: at fixed displacement, doubling speed quadruples acceleration, which is why high-speed equipment is governed by inertia loads rather than by static weight. Conversions matter in practice, with , velocity often quoted in mm/s RMS in ISO 10816 machine assessments, and displacement in micrometres peak-to-peak for bearing-housing measurements.
A useful shortcut follows from the same model: a structure that sags a known distance under a known static load has its natural frequency almost without any modal software, the same deflection route used in Trusses and Beams.
Free Vibration and Damping Ratios
With no external force, the solution depends only on . For below 1 the mass oscillates at the damped natural frequency with an exponential envelope , so each successive peak shrinks by a constant factor. At the system returns to rest in the shortest time without overshoot, and above 1 it creeps back sluggishly, which is why machinery is designed underdamped rather than near critical damping.
The logarithmic decrement converts a decay record into a damping ratio without any curve-fitting software. Measuring two successive peaks and one period apart:
The formula assumes viscous damping, but real machines dissipate energy in several ways: viscous shearing in oil films, Coulomb friction in dry joints, hysteresis in materials, and radiation into connected structures. Bolted joints behave mostly like friction, so their apparent damping grows with amplitude and their decay is not a clean exponential, while an oil film or a rubber mount is close to the viscous ideal. The preload and underhead friction behind that joint behaviour is developed in Fasteners and Bolts. When the decay is visibly non-exponential, report a damping ratio with the amplitude range it was measured over, because that number will change if the machine is run at a different level. For light damping the difference between and is second order, so the measured oscillation frequency can be used directly for in design work.
Worked Example 1: extracting stiffness and damping from a ring-down test
A 45 kg panel is struck with an instrumented hammer and its displacement decays from 4.2 mm to 3.1 mm over one cycle, with a measured oscillation frequency of 8.5 Hz. Find the damping ratio, the natural frequency, and the equivalent stiffness.
Step 1, logarithmic decrement: .
Step 2, damping ratio: , so the panel has about 4.8 percent of critical damping, typical of a bolted steel assembly with friction at the joints.
Step 3, stiffness: (the damped frequency differs from the undamped one by only at this damping), so
Step 4, use: if the fan mounted on that panel runs at 8.5 Hz (510 rpm), it sits exactly on the panel resonance and a small unbalance will shake the whole structure; either stiffen the panel to raise well above 510 rpm or add damping treatment to cap the peak.
Extracting stiffness and damping from a ring-down record is three lines of arithmetic, which is why impact testing needs no modal package for a first estimate:
import math
def ringdown(mass, x1, x2, f_hz):
"""Stiffness and damping from two successive free-decay peaks."""
delta = math.log(x1 / x2)
zeta = delta / math.sqrt(4 * math.pi ** 2 + delta ** 2)
w_d = 2 * math.pi * f_hz
w_n = w_d / math.sqrt(1 - zeta ** 2)
k = mass * w_n ** 2
return zeta, w_n, k
zeta, w_n, k = ringdown(45.0, 4.2, 3.1, 8.5)
print(f"zeta = {zeta:.3f}, f_n = {w_n / (2 * math.pi):.2f} Hz, "
f"k = {k / 1000:.1f} kN/m")
# A second strike at a different amplitude shows whether damping is amplitude dependent.
zeta2, _, _ = ringdown(45.0, 2.8, 2.2, 8.5)
print(f"lower-amplitude strike: zeta = {zeta2:.3f}")
The script returns and for the worked panel, matching the hand solution. Running the same extraction on a quieter strike separates viscous damping from joint friction: if the two damping ratios disagree noticeably, the decay is amplitude dependent and the reported value must carry the measurement range with it.
Forced Response, Resonance, and Magnification
A harmonic force does not drive the mass at its own amplitude ; it drives it amplified or attenuated depending on how close the forcing frequency sits to the natural frequency. Dividing out the static deflection gives the magnification factor in terms of the frequency ratio :
Three regimes follow. For much less than 1 the response is stiffness-controlled and approaches . For near 1 the denominator collapses to , so the peak amplitude is times the static deflection: a lightly damped system with amplifies by 25, which is exactly why a small force at resonance is destructive. For much greater than 1 the response is mass-controlled and decays as , so high-frequency excitation barely moves a heavy inertia.
The quality factor is the reciprocal of twice the damping ratio and also equals times the number of cycles in a free-decay ring-down, so it links frequency-domain and time-domain measurements of the same system. Phase matters as much as amplitude: the response lags the force by 0 degrees well below resonance, sits at 90 degrees at resonance where the motion is velocity-dominated, and approaches 180 degrees far above it. That phase flip is why balancing weights added at the wrong angular station can increase vibration instead of reducing it, and why the phase angle between the 1x force reference and the 1x displacement vector is used to locate the heavy spot on a rotor.
Energy offers a second route to the same answers: at resonance the strain energy stored in the spring equals the kinetic energy in the mass, and the energy dissipated per cycle by the damper fixes how far the amplitude can grow. This is why resonance amplitude is a damping problem and not a stiffness problem, and why structures with welded joints ( near 0.01) ring far longer than bolted or rubber-mounted ones ( of 0.05 to 0.20).
Worked Example 2: resonant amplification of a known force
A rotating machine produces a harmonic unbalance force of 40 N at its running speed. Its supporting structure has and damping ratio . Find the response at resonance and compare it with the same force applied at 3 Hz.
Step 1, static deflection equivalent: with (given by the mount designer), .
Step 2, at resonance , so the magnification factor is .
Step 3, resonant amplitude: , which is a vibration level that will damage seals and annoy an operator.
Step 4, at 3 Hz the frequency ratio is , giving , so the same force produces only 0.22 mm. Ten times the amplitude for the same force, purely because of where the excitation sits relative to the natural frequency.
Transmissibility and Isolation
Forces do not stay where they are created: the mass transmits into the foundation, and the ratio of transmitted to applied force is the transmissibility:
Two results drive all mount design. Transmissibility equals 1 at , peaks above 1 near resonance, and crosses back through 1 at regardless of damping. Beyond that point the mount isolates, and for light damping the transmission falls off as , so a mount running at passes about 1 percent of the force.
The practical trap is that softening the mount to lower also increases static sag , which costs stability and travel; air mounts and rubber isolators are chosen from the sag budget first and the frequency ratio second. Damping helps enormously at and just above resonance but slightly degrades isolation far above it, which is why a spring isolator with little damping needs snubbers or a controlled start-up ramp rather than a softer spring.
| Mount type | Usual range | Damping | Sag at that | Where it fits |
|---|---|---|---|---|
| Steel coil spring | 1.5 to 8 Hz | 0.01 to 0.02 | 10 to 110 mm | Best isolation, needs snubbers |
| Rubber or neoprene | 5 to 20 Hz | 0.05 to 0.15 | 2 to 16 mm | Compact, self-damping, aging limits |
| Air mount | 1.5 to 5 Hz | 0.10 to 0.20 | 25 to 110 mm | Heavy equipment, adjustable level |
| Viscous or viscoelastic pad | 8 to 25 Hz | 0.10 to 0.30 | 1 to 6 mm | When peak control matters more than tail |
| Squeeze-film damper | set by design | 0.10 to 0.30 | small | Rotor criticals in turbomachinery |
Selecting starts from the excitation frequency of the machine and the allowable static deflection, then checks that the resulting ratio sits comfortably beyond at every operating speed, including idle and any variable-speed range.
đĄDesign the Run-up, Not Just the Operating Point
Rotordynamics: Unbalance, Critical Speeds, and Balancing
Every real rotor has residual mass eccentricity, and the rotating force it produces is the single most common vibration source in plants:
With in kg, in m, and in rad/s, the force is in newtons and scales with the square of speed, so doubling rpm quadruples the force. The balance grade in the second relation is residual eccentricity times angular speed in mm/s, and ISO 21940-11 fixes acceptable grades by application: G6.3 for general industrial machines, G2.5 for machine-tool spindles and pumps, G1 for grinding spindles, and finer still for gyroscopes.
Static balancing corrects a single heavy spot in one plane and removes force, but it leaves a couple: two planes offset axially with equal and opposite unbalance produce no net force yet a rocking moment that separates into opposite-phase readings at the two bearings. Dynamic (two-plane) balancing corrects both, and it is mandatory for any rotor whose length is not small compared with its diameter.
Critical speeds are the lateral natural frequencies of the rotor on its bearings, including the flexibility of the shaft itself, not just the foundation. A rotor always has at least one critical below its maximum continuous speed on rigid supports, so run-up crosses it; the response at the crossing is shaped by damping from the bearings or from squeeze-film dampers. Interference diagrams (Campbell diagrams) overlay excitation orders such as 1x and 2x running speed on the speed-dependent critical-speed lines. The design rule is to leave a margin of roughly 15 to 20 percent between any continuous operating speed and a crossing, and to note every crossing on the run-up plan so the operator knows where to hurry through.
| ISO 21940-11 grade | in mm/s | Typical application |
|---|---|---|
| G1000 | 1000 | Crankshafts, loose-coupling drive shafts |
| G250 | 250 | Automotive wheels, drive shafts |
| G63 | 63 | Pump and fan impellers, general motors |
| G6.3 | 6.3 | Machine-tool drives, medium turbines |
| G2.5 | 2.5 | Machine-tool spindles, gas turbines |
| G1 | 1 | Grinding spindles, audio equipment |
| G0.4 | 0.4 | Gyroscope rotors, precision spindles |
Worked Example 3: unbalance force and balance grade at speed
A 12 kg rotor runs at 3000 rpm with a residual unbalance of 5 micrometres. Compute the rotating force, the 1x line frequency, and the balance grade.
Step 1, angular speed: .
Step 2, force: .
Step 3, spectral line: , so the analyst should see a 1x line at 50 Hz and its phase relative to a keyphasor mark.
Step 4, balance grade: .
Step 5, judgement: G1.6 beats the G2.5 normally required for precision work, yet that 5.9 N still produces millimetres of displacement if the support happens to have a mode at 50 Hz. Balancing grade alone never excuses a resonance in the operating range.
Excitation Sources and Diagnostic Signatures
Different faults write different signatures, and the spectrum is the fingerprint. Misalignment of a rigid coupling typically raises 2x running speed, sometimes to a level comparable with 1x, while pure unbalance stays at 1x with stable phase. Looseness produces harmonics and subharmonics, rolling-element bearing defects produce families of bearing-pass frequencies with sidebands, and gear meshes produce a line at tooth count times shaft speed with sidebands when a tooth is damaged. Aerodynamic and hydraulic forces add blade-pass lines at vane count times speed, while electrical machines add line frequency and its multiples.
| Source | Spectral signature | Confirming test |
|---|---|---|
| Unbalance | 1x with stable phase, amplitude grows as speed squared | Weight addition trial, phase across the critical |
| Misalignment | 2x and often 3x, axial 1x elevated | Laser alignment check, coupling inspection |
| Looseness | Harmonics, subharmonics, raised noise floor | Structural bolt torque, soft foot measurement |
| Bearing defect | Bearing-pass families with sidebands | Enveloping or demodulation, ultrasound |
| Gear damage | Mesh line plus sidebands at shaft order | Order tracking, tooth contact pattern |
| Resonance | One frequency responds strongly, 90 degree phase shift | Impact test or bump test modal survey |
| Electrical | Line frequency and its multiples | Phase comparison against power supply |
Order tracking ties spectra to the machine rather than to fixed time: a Campbell plot of order lines against speed reveals whether a peak tracks 1x (rotor problem) or stays at a fixed hertz value (structural resonance). That single distinction decides whether you balance a rotor or stiffen a frame.
Assessment also needs agreed limits. Housing vibration is usually read as broad-band velocity in mm/s RMS with zone limits from ISO 10816 (replaced in newer editions by the ISO 20816 family), shaft relative motion is read in micrometres with limits from ISO 7919, and rolling-element bearing defects are screened with enveloped acceleration or ultrasound rather than with velocity. Whichever quantity you quote, state the measurement location, the frequency band, and the machine class, because a number without those three is not a result.
The transducer choice follows the physics of the same quantity at different frequencies. Displacement probes (eddy-current, shaft relative) are sensitive at low frequency where the motion is large, velocity sensors cover the mid band where human-perceived vibration and fatigue damage live, and accelerometers cover the high band where bearing and gear defects appear, with integration done in the instrument or the analyzer. Sampling and windowing decide what the spectrum can show: a tachometer-referenced order analysis is required whenever speed drifts, and a plain fixed-sample FFT smears order lines across a moving machine.
Field cases make the pattern concrete:
- Rooftop air handler â 1x at fan speed that grows after a rotor change; two-plane balance restores the level, and the isolator sag is rechecked after the weight change.
- Centrifugal pump â elevated vane-pass line with a rising noise floor; cavitation and a partly closed discharge valve are ruled out before any balancing is attempted.
- Machine-tool spindle â a broad hump near 80 Hz that does not move with rpm; an impact test finds a column mode, so the fix is stiffness and damping, not balance.
- Gearbox stage â mesh line with one-sided sidebands; a cracked tooth is confirmed by order tracking and the drive is shut down before the crack reaches the root.
- Engine accessory drive â 2x dominant with high axial readings; coupling alignment is corrected and the vibration drops without touching the rotor.
Control Strategies and Verification
Selection is a trade study, not a preference. Detuning by adding stiffness or changing mass moves the natural frequency without adding cost, but it may violate a clearance or weight budget. Damping caps the resonant peak and shortens run-up time, at the cost of heat and some high-frequency isolation. Isolation protects the foundation but adds static deflection. Absorption uses a tuned mass-spring absorber that reacts the excitation force into the structure at exactly the offending frequency, which is how tall buildings and exhaust systems are tamed, and it works over a narrow band only.
An absorber is tuned so its own natural frequency sits at the excitation frequency, and the absorber mass is then sized from the reaction it must produce:
where is the permitted motion of the absorber mass. The classical result is that a properly tuned absorber drives the main mass to nearly zero at the design frequency, at the price of splitting the original peak into two peaks on either side, so the machine must not linger at those new resonances during a speed change.
import math
m = 200.0 # kg, machine mass on mounts
zeta = 0.05 # damping ratio of the mount system
f_exc = 30.0 # Hz, excitation (1800 rpm)
f_n = 3.0 # Hz, mount natural frequency
r = f_exc / f_n
w_n = 2 * math.pi * f_n
static_sag = 9.81 / w_n ** 2 # m under gravity
mf = 1.0 / math.sqrt((1 - r**2)**2 + (2 * zeta * r)**2) # magnification
trans = math.sqrt(1 + (2 * zeta * r)**2) / math.sqrt((1 - r**2)**2 + (2 * zeta * r)**2)
# unbalance force sweep for a 12 kg rotor with 5 micron residual unbalance
e = 5e-6
for rpm in (1000, 1800, 3000):
w = 2 * math.pi * rpm / 60.0
force = m / 10 * e * w ** 2
print(f"{rpm:5d} rpm 1x = {rpm/60:6.1f} Hz F = {force:6.2f} N")
print(f"frequency ratio r = {r:.2f}")
print(f"static sag {1000*static_sag:.1f} mm")
print(f"magnification factor {mf:.3f}")
print(f"transmitted force fraction {100*trans:.2f} percent")
print(f"resonant magnification 1/(2 zeta) = {1/(2*zeta):.1f}")
The script returns a frequency ratio of 10, a static sag of 27.6 mm, a magnification factor of 0.010 at the operating point, and 1.43 percent of the applied force transmitted into the floor, while the resonant magnification would be 10. Those four numbers are the entire mount-selection argument in one screen. Verification then closes the loop, and a disciplined sequence keeps the results defensible:
- Baseline â record spectra and phase at operating speed before any change, with the same probe location and settings.
- Bump test â confirm the installed natural frequency on the idle structure so the model is anchored to hardware.
- Run-up and coast-down â check peak amplitude at every crossing and the time spent near each critical.
- Correction trial â change one variable at a time (weight, alignment, stiffness) and repeat the same measurement.
- Sign-off â compare against the agreed zone limits and file the spectra with the machine record.
đĄConfirm With a Bump Test, Not a Guess
Common Mistakes
Isolating in the wrong region
Fix: Below <MathBlock tex={`r = \\sqrt{2}`} /> the mount amplifies; calculate the excitation frequency and the mount frequency before ordering isolators.
Balancing in one plane only
Fix: Long rotors carry a couple as well as a force; use two-plane dynamic balancing above moderate speeds.
Treating L10 style charts as universal limits
Fix: Vibration standards depend on machine class and measurement quantity; state whether you are reading displacement, velocity, or acceleration and in which band.
Adding damping everywhere
Fix: Damping caps the peak but slightly reduces isolation above resonance and adds heat; apply it where the response is governed by the peak.
Key Takeaways
- Natural frequency comes from stiffness over mass: <MathBlock tex={`\\omega_n = \\sqrt{k/m}`} />, and damping ratio from <MathBlock tex={`c`} /> over critical damping.
- Resonant amplitude is limited to roughly <MathBlock tex={`1/(2\\zeta)`} /> times static deflection, so light damping demands detuning rather than reliance on the peak.
- Isolation only begins beyond a frequency ratio of <MathBlock tex={`\\sqrt{2}`} />, and the mount sag budget usually sets a practical lower bound on <MathBlock tex={`f_n`} />.
- Unbalance force grows with speed squared: <MathBlock tex={`F = me\\omega^2`} />, and balance grades from ISO 21940-11 fix the acceptable residual.
- Detune, damp, isolate, or absorb, and verify the installed machine with a bump test and order-tracked spectrum.
Frequently Asked Questions
What is resonance?
Resonance is the condition where excitation frequency coincides with a natural frequency, so the denominator of the response function collapses to and amplitude peaks at about times the static deflection. Phase passes through 90 degrees at that point, which is a reliable experimental marker.
Why are critical speeds dangerous?
A critical speed is a lateral natural frequency of the rotor on its bearings, so sustained operation there multiplies the unbalance response, loads the bearings, and can drive the shaft into rub. Run-up and coast-down must cross quickly or dwell only where damping limits the amplitude.
Does damping always help?
Damping reduces the resonant peak, shortens run-up, and damps noise, but far above resonance it slightly reduces isolation effectiveness and adds heat. The right amount is where the response near the peak matters more than the transmission tail.
How do you tell unbalance from misalignment in a spectrum?
Unbalance shows a dominant 1x line with stable phase that grows with speed squared; misalignment raises 2x (and often 3x) and typically shows high axial vibration. Confirm with a phase measurement across the coupling and a laser alignment check before changing weights.
Interview Questions
Q1: A fan vibrates badly at operating speed. How do you proceed?
Take a spectrum and phase: dominant 1x with good phase repeatability points to unbalance; a structural peak that stays at fixed hertz while speed changes points to resonance, so run a bump test and stiffen or detune; elevated 2x points to misalignment, so check the coupling first.
Q2: Explain the magnification factor.
It is dynamic amplitude divided by the static deflection that the same force would produce, a function only of frequency ratio and damping ratio; at resonance it equals <MathBlock tex={`1/(2\\zeta)`} />, so 5 percent damping gives a factor of 10.
Q3: What is the practical limit of a soft mount?
Static sag. A 3 Hz mount needs about 27 mm of sag under gravity, so the equipment must tolerate that deflection and the isolation gain must justify the loss of stiffness and stability.
Q4: Why does phase matter when balancing?
The angle between the 1x force reference and the 1x response identifies the angular position of the heavy spot; weights added without phase information can add to the unbalance instead of cancelling it.