Heat Transfer: Conduction, Convection, and Radiation
What You'll Learn
- 1Build and solve thermal resistance networks for plane walls, cylinders, and composite sections
- 2Apply Biot and Fourier numbers to choose lumped or distributed transient analysis
- 3Select convection coefficients from forced and natural convection correlations with the right driving temperature
- 4Compute radiative exchange with view factors and surface resistances
- 5Rate heat exchangers with LMTD or effectiveness-NTU and derate them for fouling
Heat moves by three mechanisms, and nearly every thermal design problem is a combination of them. Conduction transfers energy through a solid (or stagnant fluid) by molecular interaction, governed by material conductivity and geometry. Convection combines conduction at a surface with the bulk motion of a fluid, so the coefficient depends on the flow as much as on the fluid. Radiation exchanges energy by electromagnetic waves and needs no medium at all, so it dominates wherever temperatures are high or convection is absent. Design questions then reduce to three numbers: the rate of energy transferred, the temperature difference driving it, and the resistance in the path.
These three modes show up together in furnace walls, electronics cooling, heat exchangers, building envelopes, and the thermal management of any machine. The strategy is always the same: draw the path, put a resistance or a coefficient on each leg, write the balance, and check whether the assumption (steady, one-dimensional, constant properties) still holds when the numbers come out, as the cycle context is developed in Thermodynamics Fundamentals.
Before any formula, estimate which mode dominates, because the order of magnitude decides how precise the rest of the work needs to be:
| Situation | Usually dominant | Why |
|---|---|---|
| Thick solid wall at moderate temperature | Conduction | Large contrast against the gas film on each side |
| Fast liquid flow over a surface | Convection | High overwhelms radiation at low surface temperature |
| Still air near a hot surface | Convection and radiation together | Weak film makes radiation comparable |
| Furnace interior or exhaust duct | Radiation | Fourth-power term beats weak convection |
| Vacuum electronics or spacecraft | Radiation only | No fluid to convect |
| Thin interface between clamped parts | Contact conduction | Often the largest single resistance in the path |
Conduction and Thermal Resistance Networks
Fourier's law states that heat flux is proportional to the negative temperature gradient:
The minus sign is the sign convention: heat flows down the temperature gradient. Conductivity is a true material property, and it varies strongly with temperature for metals (pure copper near 400 W/(m K) at room temperature, dropping with alloying and temperature) and with density and moisture for insulations, where as low as 0.03 to 0.05 W/(m K) is achieved by trapping still gas in pores.
Because the steady one-dimensional form is linear, thermal resistance is defined the same way an electrical resistance is, with temperature difference taking the place of voltage:
| Geometry | Thermal resistance | Notes |
|---|---|---|
| Plane wall | Layers add in series | |
| Composite wall | Sum of | Overall |
| Cylindrical shell | Pipes, ducts, reactor vessels | |
| Spherical shell | Pellets, bearings | |
| Inner surface convection | Film resistance | |
| Outer surface convection | Film resistance | |
| Fouling deposit | Added on each side, grows with service | |
| Contact resistance | Scales with pressure and surface finish |
Series resistances add; parallel paths (heat leaking through a stud and through the cavity in a wall, for instance) add as reciprocals. For a cylinder the overall conductance is often written as a product using the log-mean area , which is the only correct area to pair with a temperature difference when the flux is not uniform. The whole method looks like this:
T_gas T_s,i T_1 T_2 T_s,o T_air
o----[1/h_i A]---+---[L1/k1A]---+---[L2/k2A]---+---[1/h_o A]---o
| | |
driving potential: T_gas - T_air = Q * (sum of all R)
temperature drops in proportion to each resistance
current analogy: Q (W) <-> I (A), R (K/W) <-> R (ohm)
Writing the network before touching a calculator is the single habit that prevents the most common thermal errors: using the wrong area for a film, forgetting that a cylinder's area grows along the path, or dropping a resistance that turns out to dominate.
Worked Example 1: furnace wall with film resistances
A furnace wall is 0.25 m of refractory () behind 0.08 m of mineral insulation (). Hot gas is at 900 degrees Celsius with ; outside air is at 30 degrees Celsius with . Find the heat flux and the interface temperatures.
Step 1, resistances per square metre: , , , , giving .
Step 2, flux: .
Step 3, step across each resistance: degrees Celsius, degrees Celsius, degrees Celsius, and the outer surface closes at degrees Celsius.
Note where the temperature drops: most of the 870 K difference falls across the insulation, and only 18 K across the hot gas film, so improving buys almost nothing while a small change in insulation thickness or conductivity moves the heat loss significantly.
Transient Conduction: Lumped Capacitance and Time Constants
Nothing in service is truly steady from the first minute. When a body is suddenly exposed to a new environment, the question is whether the internal conduction resistance is small compared with the surface film resistance, and the Biot number answers it:
For below about 0.1, temperature inside the body is uniform to within 5 percent of the driving difference, and the lumped-capacitance model applies: the body temperature decays exponentially toward the environment with a time constant , giving . For larger the spatial gradient matters, and the solution becomes a series expansion in eigenfunctions (Heisler charts or one-term approximations for simple slabs, cylinders, and spheres), with the Fourier number setting the dimensionless time, where thermal diffusivity is .
Worked Example 2: quenching a plate and validating the lumped assumption
A 3 mm aluminium plate (, , ) at 200 degrees Celsius is cooled by still air at 25 degrees Celsius with on both faces. Find the Biot number, the time constant, and the time to reach 50 degrees Celsius.
Step 1, characteristic length for a plate cooled on both faces: , so , far below 0.1 and comfortably lumped.
Step 2, time constant: .
Step 3, target time: , so , about 7.9 minutes.
The same aluminium as a 100 mm casting would have with air but roughly 0.7 with an oil quench, where lumped analysis fails and the surface cools much faster than the core, which is exactly the condition that causes quench cracking.
Convection: Physics, Correlations, and Coefficients
Newton's law of cooling is a definition dressed as a law: . Everything difficult about convection is hidden in , which is not a material property but a result of the flow, the geometry, the surface condition, and the fluid properties. Typical magnitudes set expectations before any calculation:
| Regime | Typical in | What governs it |
|---|---|---|
| Natural convection, gases | 2 to 25 | Buoyancy, , characteristic length |
| Natural convection, liquids | 100 to 1000 | Buoyancy and conductivity of the liquid |
| Forced convection, gases | 25 to 250 | Velocity, turbulence, geometry |
| Forced convection, liquids | 100 to 2000 | Velocity and property ratios |
| Boiling and condensation | 2500 to 100000 | Phase change, latent heat, bubble dynamics |
Correlations collapse experiments into dimensionless groups. Forced convection is built on the Nusselt number , the Reynolds number (inertia versus viscosity), and the Prandtl number (momentum versus thermal diffusion). The classic Dittus-Boelter correlation for fully developed turbulent flow in a smooth pipe, with for heating and 0.3 for cooling, is accurate within about 20 percent in its range of above 10,000 and between 0.6 and 160.
Natural convection replaces Reynolds with the Grashof number (buoyancy versus viscosity) and uses the Rayleigh number ; Churchill and Chu give a single correlation covering laminar and turbulent vertical plates. Property evaluation temperature matters: properties are taken at the film temperature , and using the wrong one shifts by 10 percent or more. Entry regions are not fully developed, so short tubes and leading edges see higher than fully developed values, while rough surfaces and promoters raise at the cost of pressure drop, a trade that is only worth it when pumping power is cheap relative to the hardware saved in the exchanger.
Radiation Exchange
Every surface above absolute temperature emits energy at a rate given by the Stefan-Boltzmann law:
with in kelvin always. Real surfaces emit a fraction of the blackbody value, absorb a fraction of incident radiation, reflect the rest, and (for translucent media) transmit some. Kirchhoff's law ties them together at equilibrium: at the same wavelength and temperature. View factors account for geometry, and they must satisfy the summation rule for an enclosure, which prevents the classic error of assuming a surface sees all of another one when it is partly shadowed.
For two large parallel black plates the net exchange is simply ; adding surface resistance for gray diffuse emitters gives the familiar two-surface result with denominator . With , , and , the denominator is 2.75 and the net flux is .
Radiation often matters more than intuition suggests even at modest temperatures. A pipe surface at 500 K with in air at 298 K loses by convection and by radiation, so radiation is half the total loss from an uninsulated hot line. Selective surfaces exploit the difference between solar wavelengths (high absorptance wanted in a collector) and thermal infrared (low emittance wanted to keep heat in), which is the entire physics of a solar thermal absorber plate or a low-emissivity window film. Radiation matters most in vacuum or microgravity where convection is absent, at furnace and re-entry temperatures where the fourth power explodes, and whenever surfaces see each other with large view factors.
Fins and Extended Surfaces
When the surface film dominates the resistance, the fix is more surface: a fin raises the effective area while its own conduction resistance limits how much of the tip actually participates. For a straight fin with adiabatic tip, temperature decays as with , and the fin efficiency is
A 2 mm aluminium fin () of 25 mm length in air with has and, with the corrected length , giving percent. Push the same fin to 100 mm and efficiency falls to about 58 percent while total heat flow barely moves beyond its 50 mm value, so the design rule is that fins pay only when they are short, thin, and made of high-conductivity material, and only where is low (gas side) rather than where the film already conducts well (liquid side). Spacing matters too: fins packed closer than roughly the boundary-layer thickness interfere with each other, drops, and pressure drop climbs.
An array is rated with the overall surface efficiency , where fins share the total area , and the design equation becomes . Real heat sinks add spreading resistance between the chip and the fin base, which is why a solid copper slug or vapour chamber under the fins often buys more than another row of aluminium.
Insulation, Critical Radius, and Surface Treatments
Insulation design is conduction with a moving boundary, because the outer radius of the layer changes the convection area as well as the conduction resistance. For a bare cylinder the total resistance is , and differentiating with respect to shows the resistance is at a minimum at
Below that radius, adding insulation makes losses worse; above it, every additional layer helps. For typical fibrous insulation at in still air at , the critical radius is 4 mm, so any pipe larger than 8 mm outside diameter benefits immediately, and only very fine electrical wires ever sit in the penalty zone. The same calculation for a sphere (a catalyst pellet or a bearing ball) gives twice the radius.
Practical insulation work also has to respect moisture, movement, and surface temperature limits. Vapour barriers stop the insulation from absorbing water, because a wet insulation can lose half its performance as water replaces the trapped gas; supports and hangers create thermal bridges that must be sized; and personnel-protection surfaces are limited to roughly 60 to 70 degrees Celsius on valves and pipe. Pipe and vessel insulation is specified by system (rigid boards, foamglas, mineral wool, aerogel) against conductivity measured per ASTM C518 or an equivalent guarded hot plate method, and the installation standard EN ISO 12241 sets the mechanical requirements and the surface temperature criteria.
Surface treatments are the cheap lever on the other side of the resistance. A low-emissivity aluminium jacket over insulation cuts the radiative exchange from the outer cladding, which matters on hot equipment; a high-emissivity coating on an electronics enclosure does the opposite and helps it shed heat. Painting, cladding, and fouling all change far more than they change , and on a hot bare surface, where radiation can be half the loss, that is a real design variable rather than a cosmetic one.
| Choice | Governing question | Typical consequence |
|---|---|---|
| Thicker insulation | Is the radius above critical, and what is the marginal gain? | Loss falls with , so returns diminish fast |
| Higher-grade material | Does conductivity justify the cost at the operating temperature? | Aerogel or foamglas saves space, not always money |
| Low-emissivity cladding | Is the outer surface hot enough for radiation to matter? | Cuts cladding loss 30 to 50 percent on hot lines |
| Personnel protection | Is the accessible surface below the safety limit? | Adds thickness independent of energy economics |
| Moisture control | Can vapour condense inside the layer? | Water can double effective conductivity |
Heat Exchangers: LMTD and Effectiveness-NTU
A heat exchanger packages convection and conduction into a surface that lets two streams exchange duty without mixing. Two methods cover the two standard situations. The LMTD method uses with
where the two end differences are taken in counterflow (or with a correction factor for shell-and-tube passes, ). The effectiveness-NTU method is used when inlet conditions and duty are fixed but outlet temperatures are unknown: with , and . The temperature profiles look like this:
counterflow parallel flow
T | T |
| \ hot | \ hot
| \ | \
| \ | \
| \ cold (flows the other way) | \
| \ | \ cold
|______\_______> position |________\___> position
Tin_h Tout_h Tout_c Tin_c both inlets at the left,
smallest difference at the right end gaps always larger
In counterflow the two streams approach each other everywhere, so the local driving difference stays small and positive; in parallel flow the cold stream can never exit above the hot stream outlet, which is the physical reason the correction factor and the pass arrangement decide whether a shell-and-tube unit can legally do its duty.
| Method | Use when | Strength | Trap |
|---|---|---|---|
| LMTD with correction | All four temperatures are known | Direct sizing of area | drops sharply in some pass arrangements |
| Effectiveness-NTU | Duty and inlets known, outlets unknown | Ratings and off-design checks | Capacity-ratio branches must be selected correctly |
| P-NTU (enthalpy rows) | Phase change or variable properties | Boilers, condensers, evaporators | Needs iterative property updates |
| Fouling factors | Service data available | Keeps clean exchanger viable when dirty | Over-fouling penalties the first day of operation |
Worked Example 3: counterflow oil cooler with LMTD and area sizing
Water is cooled from 80 to 40 degrees Celsius at 2.0 kg/s () by oil entering at 30 degrees Celsius at 6.0 kg/s with . Assume and find duty, oil outlet temperature, LMTD, required area, and whether parallel flow could do the job.
Step 1, duty: .
Step 2, oil outlet: degrees Celsius.
Step 3, counterflow differences: K, K, so K.
Step 4, area: , so with the surface is .
Step 5, parallel flow check: the oil could never leave above the water exit of 40 degrees Celsius, so a 56.5 degrees Celsius outlet is impossible in parallel; counterflow is required for this duty.
Real exchangers are derated twice: by a fouling allowance added to each side (typically 0.0001 to 0.0005 for clean water, more for dirty or biologically fouled service, per TEMA and API 660 practice), and by a pressure-drop budget that limits velocity. Cleaning frequency is an economic decision: design fouling factor too large and the exchanger costs more on day one, too small and it is undersized after a season.
import math
def lmtd(dT1, dT2):
if abs(dT1 - dT2) < 1e-6:
return dT1
return (dT1 - dT2) / math.log(dT1 / dT2)
def epsilon_ntu_counter(NTU, Cr):
if math.isclose(Cr, 1.0):
return NTU / (1 + NTU)
return (1 - math.exp(-NTU * (1 - Cr))) / (1 - Cr * math.exp(-NTU * (1 - Cr)))
def fin_efficiency(mL):
return math.tanh(mL) / mL
# Worked Example 3: counterflow oil cooler
mw, cpw, dTw = 2.0, 4.18, 40.0 # kg/s, kJ/(kg K), K drop
mo, cpo, Tin_o = 6.0, 2.1, 30.0
Q = mw * cpw * dTw # kW
Tout_o = Tin_o + Q / (mo * cpo)
dT1, dT2 = 80.0 - Tout_o, 40.0 - Tin_o
print(f"duty {Q:.1f} kW, oil out {Tout_o:.1f} C, LMTD {lmtd(dT1, dT2):.1f} K")
UA = Q / lmtd(dT1, dT2)
U = 350.0
print(f"UA {UA:.1f} kW/K, area {1000*UA/U:.1f} m2")
# Fouling derates the clean design once deposits grow
Rf_total = 0.0002 * 2 # m2 K/W, both sides combined
A = 1000 * UA / U # m2 required surface
UA_fouled = 1.0 / (1.0 / (1000 * UA) + Rf_total / A) # W/K
print(f"UA {UA:.1f} kW/K clean, {UA_fouled/1000:.1f} kW/K after fouling")
# Fin efficiency sweep: 2 mm aluminium fin, h = 50
h, k, t = 50.0, 200.0, 0.002
m = math.sqrt(2 * h / (k * t))
for L in (0.025, 0.050, 0.100):
mL = m * (L + t / 2)
print(f"fin L {1000*L:5.1f} mm mL {mL:4.2f} efficiency {100*fin_efficiency(mL):5.1f} percent")
# Effectiveness check for a counterflow unit
NTU, Cr = 1.5, 0.5
print(f"NTU {NTU}, Cr {Cr} -> effectiveness {100*epsilon_ntu_counter(NTU, Cr):.1f} percent")
The script reproduces the cooler at 334.4 kW duty, 56.5 degrees Celsius oil outlet, 15.8 K LMTD, and 60.5 square metres of area, then shows fin efficiency falling from 94.7 percent at 25 mm to 82.8 percent at 50 mm and 57.7 percent at 100 mm, a counterflow unit at NTU 1.5 with capacity ratio 0.5 reaching 69.1 percent effectiveness, and fouling taking the 21.2 kW/K clean design down to 18.6 kW/K. All four numbers carry the same lesson: geometry, surface condition, and flow decide how close a real device gets to the ideal limit.
đĄPick the Temperature Difference Correctly
đĄMeasure Conductivity and Fouling, Do Not Assume Them
Common Mistakes
Treating the convection coefficient as a material property
Fix: h changes with velocity, geometry, surface finish, and fluid properties; evaluate correlations at the film temperature and re-check whenever the geometry moves.
Using the arithmetic mean temperature difference
Fix: Heat exchangers need LMTD or effectiveness-NTU; the arithmetic mean misrates duty whenever the temperature profile is curved.
Ignoring contact and fouling resistance
Fix: Clamped joints without interface material show large temperature drops under heat flux, and a clean-side design without fouling factors fails after a season.
Adding insulation below the critical radius
Fix: For small cylinders and spheres compute the critical radius from insulation conductivity over h first; below it, more material increases the loss.
Key Takeaways
- Conduction follows conductivity and geometry, convection follows the film coefficient and flow, and radiation follows absolute temperature to the fourth power.
- Thermal resistance networks unify multi-mode paths, and the largest resistance in the chain is where design effort belongs.
- A Biot number below about 0.1 permits lumped-capacitance analysis with an exponential time constant of rho c V over h A.
- Exchanger duty is UA times the driving temperature difference, and counterflow maximises that difference for a given area.
- Fouling, moisture, and contact resistances appear in service, so they must be sized in the design rather than discovered in the field.
Frequently Asked Questions
What is the critical radius of insulation?
For a bare small cylinder or sphere, adding insulation increases the outer area faster than it adds conduction resistance, so total heat loss rises until the radius reaches (for a cylinder) or (for a sphere). Beyond that point, more insulation always reduces loss. For room-scale pipes the critical radius is only a few millimetres, so extra insulation helps immediately.
Why is counterflow better than parallel flow?
Counterflow maintains a positive temperature difference along the entire length with the smallest area for a given duty, lets the cold outlet approach the hot inlet closely, and can heat the cold fluid above the hot fluid outlet temperature, which parallel flow can never do. The penalty is mechanical: two passes in opposite directions need a more complex header arrangement.
How does fouling change the design?
Fouling adds a resistance that grows with operating time, so a design that meets duty when clean will fail when dirty. Design therefore includes fouling factors on both sides, and the choice of their magnitude trades capital cost against cleaning frequency and is governed by standards such as TEMA and API 660 for shell-and-tube units.
When can I use the lumped-capacitance model?
When the Biot number based on the characteristic length is below about 0.1, meaning internal conduction equalises temperature far faster than the surface film can remove it. Thin metals in gas pass easily; large castings in liquid or oil quenches do not, and those need the spatial transient solution or numerical analysis.
Interview Questions
Q1: How would you size a shell-and-tube cooler?
Fix the duty from the stream enthalpy change, choose counterflow LMTD and apply the TEMA correction factor for the pass arrangement, estimate clean U from correlations, add fouling resistances, solve for area, then pick tube count, diameter, pitch, and baffle spacing so pressure drop stays inside the pumping budget with velocity high enough to limit fouling.
Q2: Your heat exchanger underperforms after six months. How do you investigate?
Compare measured LMTD against design, back-calculate the current UA, then split out fouling by measuring pressure drop and taking a thermal performance test; check for non-condensables, air binding, channel maldistribution, and bypass or leakage in the shell before ordering cleaning.
Q3: When is radiation the dominant mode?
At high absolute temperature such as furnaces or re-entry, in vacuum or microgravity where convection cannot operate, and in low-velocity situations with large view factors where the fourth-power term beats a weak film coefficient. Always estimate it before ignoring it.
Q4: Why does a fin stop being useful beyond a certain length?
The fin tip falls toward ambient temperature, so added length contributes almost no heat while still costing material; efficiency falls as tanh(mL) over mL, and total heat flow asymptotes. That is why heat sinks use many short, thin, high-conductivity fins instead of a few deep ones.