Pipe Flow Friction Factor and the Moody Chart
What You'll Learn
- 1Apply the Darcy-Weisbach equation with the correct velocity head
- 2Locate the laminar, smooth, transition, and fully rough regimes
- 3Solve Colebrook-White iteratively to a converged friction factor
- 4Choose realistic roughness values and convert head loss to pressure drop
Sizing a pipeline without friction is sizing it wrong, because distributed wall shear usually dominates the head budget in any run longer than a few diameters. This lesson turns that shear into a friction factor you can look up or calculate, explains the three regions of the Moody chart, and solves the implicit Colebrook-White relation by iteration on real numbers. By the end you will take a diameter, roughness, and flow rate to a pressure drop in pascals in under a minute.
Theory and Foundations
The Darcy-Weisbach Head Loss
Darcy-Weisbach states that head loss equals friction factor times length over diameter times velocity head, and it applies to any Newtonian fluid in laminar or turbulent flow provided the right factor is used.
The first form gives head in meters of the flowing fluid, the second gives pressure loss in pascals, and both are the same statement. Watch the conventions: the Darcy factor equals four times the Fanning factor common in heat transfer, so laminar flow reads 64/Re here and 16/Re there. Mixing the two makes losses four times too large or four times too small.
The Laminar Line
In laminar pipe flow the friction factor follows from the Hagen-Poiseuille pressure drop, which is linear in velocity, and the algebra turns that linearity into a pure Reynolds number result.
Because f depends only on Reynolds number, roughness is irrelevant: the viscous layers shield the wall imperfections from the core. The line is straight on the log-log Moody chart with slope minus one, giving f = 0.064 at Re = 1000 and f = 0.0278 at Re = 2300.
Colebrook-White and the Chart Regions
Turbulent flow needs the Colebrook-White relation, which blends smooth-wall and rough-wall behavior and is implicit in the friction factor because f appears on both sides.
For routine spreadsheets an explicit approximation avoids the iteration, the Swamee-Jain formula, which agrees within a few percent.
The Moody chart plots f against Reynolds number with relative roughness as parameter. On the left the laminar line is straight and roughness free. In the smooth-pipe zone f keeps falling as Reynolds number rises, because the viscous sublayer covers the roughness. In the fully rough zone the protrusions break through that sublayer, pressure drag on them controls the loss, and f depends on relative roughness alone.
Between the smooth and fully rough limits sits the transition zone, where both terms in Colebrook-White matter: commercial steel at relative roughness 0.00045 gives f near 0.0186, while riveted steel at 0.003 gives about 0.026.
Noncircular Sections and the Working Order
Noncircular ducts use the hydraulic diameter, which reduces to the true diameter for a circle and makes the same equations usable for rectangles and annuli.
Here A is the cross-sectional area and P is the wetted perimeter. The working order for any problem is fixed: diameter, area, velocity, Reynolds number, relative roughness, friction factor, head loss, then pressure drop.
Key Formulas
Converting head loss to pressure drop multiplies by rho g, so 3.8 m of water head is 9790 x 3.8 = 37.2 kPa, and the hydraulic diameter generalizes the whole method to any duct shape.
Worked Examples
| Material | Absolute roughness epsilon | Typical relative roughness at 100 mm |
|---|---|---|
| Drawn tubing and PVC | 0.0015 mm | 0.000015 |
| Commercial steel | 0.045 mm | 0.00045 |
| Galvanized iron | 0.15 mm | 0.0015 |
| Cast iron | 0.26 mm | 0.0026 |
| Riveted steel | 3.0 mm | 0.030 |
| Concrete | 0.3 to 3 mm | 0.003 to 0.03 |
Real-World Examples
- 100 m steel main - With f = 0.0186 at 2 m/s in a 100 mm pipe, head loss is 3.79 m, about 37 kPa, and 581 W of pump power.
- PVC versus steel - Relative roughness 0.000015 for 100 mm PVC gives f near 0.0157, some 15 percent below new steel.
- Laminar oil line - At Re = 1000 the Darcy factor is 0.064, more than three times the turbulent value at the same Reynolds number.
- Riveted penstock - Roughness of 3 mm in a 1 m conduit gives epsilon/D of 0.003 and f near 0.026, worth extra head on every turbine start.
đĄIterate From a Good Starting Point
Common Mistakes
Mixing Darcy and Fanning friction factors
Fix: Confirm the convention, since Fanning is one quarter of Darcy and only Darcy pairs with velocity head V^2/2g.
Using new pipe roughness for aged pipe
Fix: Apply an aging allowance or back-calculate the effective roughness from a measured pressure drop.
Using nominal pipe diameter instead of bore
Fix: Look up the actual inside diameter for the schedule, since nominal sizes do not match the bore.
Key Takeaways
- Darcy-Weisbach multiplies length over diameter by velocity head, always with the Darcy factor.
- Laminar friction is 64/Re and ignores roughness; fully rough friction depends on relative roughness alone.
- Colebrook-White is implicit, while Swamee-Jain is explicit and seeds it to within a few percent.
- Hydraulic diameter extends the method to ducts, and roughness dominates the final answer.
Frequently Asked Questions
What is the difference between Darcy and Fanning friction factor?
Darcy equals four times Fanning, and only Darcy pairs with velocity head V squared over 2g; mixing them shifts every head loss by a factor of four.
Why does friction factor stop changing at high Reynolds number?
The viscous sublayer thins below the roughness height, so pressure drag on the roughness elements alone governs the loss and Reynolds number drops out.
How do I handle a circular pipe running half full?
Compute area and wetted perimeter for the partial section, take the hydraulic diameter or radius, and use the same correlations with care for the free surface.
Interview Questions
Q1: Water at 2 m/s flows through 100 m of 100 mm commercial steel pipe. Compute head loss.
Re is about 200000 and epsilon/D is 0.00045, so f is 0.0186, and hf = 0.0186 x 1000 x 0.204 = 3.79 m.
Q2: When is the Moody chart unnecessary?
In laminar flow where f = 64/Re, and in fully rough flow where relative roughness alone fixes f through the von Karman relation.