Pressure Measurement and Hydrostatic Forces
What You'll Learn
- 1Convert between gauge, absolute, and vacuum pressure and pick the reference
- 2Reduce a U-tube or differential manometer reading to a pressure difference
- 3Derive the resultant hydrostatic force and center of pressure on a plane surface
- 4Check buoyant force and metacentric height for a floating body
A pressure reading is meaningless without its reference, and a submerged plate cannot be sized until both the load and its point of application are known. This lesson links the instruments engineers read, from U-tube manometers to strain-gauge transducers, with the calculations that size dam gates, tank walls, and ship hulls.
Theory and Foundations
Pressure Scales and Reference States
Absolute pressure counts from a perfect vacuum, gauge pressure from local atmosphere, and a vacuum reading is a negative gauge value. Standard atmosphere is 101325 Pa and supports 760 mm of mercury at 13595 kg/m3.
A 300 kPa gauge reading is 401.3 kPa absolute and minus 40 kPa gauge is 61.3 kPa absolute. Differences match in either scale, but boiling depends on absolute pressure, so suction lines must be converted before judgment.
Manometers and Mechanical Gauges
A piezometer tube reads local pressure as a single liquid column and works only for positive gauge pressure. A U-tube reads the difference between two tapping points, and walking around the tube gives the manometer equation.
rho_m is the manometer fluid, rho_f the working fluid, and h the deflection, so 0.5 m of water stands only 0.5 x 998 / 13595 = 0.037 m of mercury. Instrument choice follows range and resolution: a Bourdon dial gives about 0.25 percent of full scale and a piezoresistive transducer nearer 0.1 percent, so a 10 bar instrument reading 1 bar wastes its tolerance on zero offset.
Force and Center of Pressure on a Plane Surface
Take a plane surface inclined at angle theta, with y measured along the plate from where the plate plane meets the surface. Pressure acts normal to the plate, so integrate over the area.
The integral of y dA is the centroidal coordinate times the area, so the resultant equals the pressure at the centroid multiplied by the whole area, whatever the shape or inclination. The force does not act at the centroid, because pressure grows with depth, so taking moments about the centroidal axis locates the point of application.
I_xx,c is the second moment about the centroidal axis and the correction is always positive, so the center of pressure always sits below the centroid. For a rectangle of width b and height H with its top at the surface, y_c = H/2 and I_xx,c = b H^3 / 12, which gives y_p = 2H/3, so the plate loads two thirds of the way down.
For curved surfaces pressure still acts normal everywhere, so the result splits into the force on the vertical projection plus the weight of fluid above the curved face.
Buoyancy and Stability
Archimedes' principle gives an upward force equal to the weight of fluid displaced, acting through the centroid of the displaced volume, the center of buoyancy.
Balance alone is not stability: the metacenter sits BM above the center of buoyancy, and metacentric height from the center of gravity must stay positive.
Once GM turns negative under a small heel, the righting arm changes sign and the body capsizes instead of returning upright.
Key Formulas
The buoyant force uses the displaced volume in m3, and GM stays positive with BM = I / forall, where I is the waterplane second moment of area.
Worked Examples
| Instrument | Typical accuracy | Best application |
|---|---|---|
| Piezometer tube | One liquid column, no moving parts | Tank wall and dam checks |
| U-tube manometer | About 1 mm of head | Laboratory verification |
| Bourdon gauge | 0.25 percent of full scale | Plant panels up to 700 bar |
| Piezoresistive transducer | 0.1 percent of full scale | Orifice and differential monitoring |
| Deadweight tester | 0.02 percent of reading | Calibration reference |
Real-World Examples
- Barometer reading - 760 mm of mercury at 13595 kg/m3 gives 101.3 kPa, so a station at 1500 m reads near 85 kPa.
- Sluice gate load - A gate 4 m wide and 2 m high with its top at the surface carries 998 x 9.81 x 1.0 x 8 = 78.3 kN at 1.33 m rather than the 1.0 m centroid.
- Ship displacement - Pushing aside 5000 m3 of seawater at 1025 kg/m3 supports 50.3 MN, so cargo is read from the draft marks.
- Suction reading - 840 mm of mercury vacuum means 110 kPa absolute, which clears the 2.34 kPa vapor pressure of water.
đĄCheck the Zero Before the Reading
Common Mistakes
Treating the centroid as the center of pressure
Fix: Apply yp = yc + I/(yc A), since pressure increases with depth and pulls the resultant down.
Mixing gauge and absolute in a suction check
Fix: Add atmospheric pressure before comparing with vapor pressure, then state which scale you used.
Using a horizontal projection for an inclined plate
Fix: Use the full area with the centroid depth for planar surfaces; projections belong to curved surface components.
Key Takeaways
- Gauge plus atmospheric gives absolute, the only valid basis for any vapor pressure comparison.
- The resultant equals centroid pressure times area, F = rho g hc A, whatever the plate shape.
- Center of pressure falls below the centroid by I/(yc A), because pressure grows with depth.
- Positive metacentric height, not force balance alone, keeps a floating body upright.
Frequently Asked Questions
Why does the center of pressure sit below the centroid?
Pressure rises with depth, so the lower half carries more load and drags the resultant down by I_xx,c / (y_c A).
What does a negative gauge reading mean?
A vacuum reading: minus 40 kPa gauge is 61.3 kPa absolute, and only that absolute value may be compared with vapor pressure.
How do I size a vertical rectangular gate quickly?
Multiply centroid depth by area and density for the force, then add the inertia term; with the top at the surface the result is rho g H^2 b / 2 at two thirds of H.
Interview Questions
Q1: A tank wall 3 m wide and 2 m high holds 2 m of water against its face. Find the force.
F = 998 x 9.81 x 1.0 x 6 = 58.7 kN, acting two thirds down at 1.33 m, since the top is at the surface.
Q2: How would you verify a pressure transducer in the field?
Compare it with a calibrated manometer at zero and at two spanning points, then confirm the error stays inside the stated 0.1 percent of full scale.