Risk Assessment and ISO 13849 Performance Levels

Industrial Automation & PLCSafety EngineeringđŸŸĸ Free Lesson

Risk Assessment and ISO 13849 Performance Levels

What You'll Learn

  • 1Run a structured machinery risk assessment
  • 2Specify safety functions with required PL
  • 3Achieve a PL using category, MTTF, and DC
  • 4Validate and document the safety design

Risk assessment determines how safe is safe enough, and ISO 13849 shows how to build safety functions that meet that target. The process starts by defining machine limits, identifying hazards, estimating and evaluating risk, then applying the hierarchy of risk reduction. The residual risk left after design measures sets the required performance level for each safety function, which engineering then achieves and validates.

Hazard Identification and Risk Evaluation

ISO 12100 frames the process: define the limits of the machinery including use, space, time, and life cycle, identify hazards from mechanical, electrical, thermal, noise, material, and ergonomic sources, then estimate risk from severity, frequency and duration of exposure, and possibility of avoidance. Risk evaluation decides whether the estimate is acceptable or further reduction is needed.

The hierarchy of risk reduction is strict: first design out the hazard with inherently safe measures, then apply safeguarding and complementary protective measures against remaining risk, and finally provide information for use such as warnings and procedures. Guards and devices come after design changes, not instead of them, and any residual risk must be disclosed in the documentation.

Performance Levels and Achieving Them

A safety function is specified with a required performance level from the risk assessment, then implemented with an architecture described by a category. Category B and 1 provide basic or single channel solutions for lower requirements, category 2 checks the function at a defined interval, category 3 tolerates a single fault with fault accumulation not leading to loss, and category 4 avoids loss of function with fault tolerance.

Achieving a level combines the category with mean time to dangerous failure of components, average diagnostic coverage, and common cause failure measures such as diversity, separation, and overvoltage protection. The resulting probability of dangerous failure per hour is computed and compared with the target band. Common cause failure is scored with a checklist so design discipline is documented rather than assumed.

Validation and Documentation

ISO 13849-2 requires validation that combines analysis of the design with testing of the installed function, including fault injection where practical. Every safety function gets a data sheet holding its description, required and achieved performance level, category, component data, diagnostic coverage, and test results. Proof test intervals and maintenance requirements follow from that analysis.

Documentation is what an auditor and the next engineer read: the risk assessment, the safety function specifications, the calculations, the wiring and program review, and the validation records. Change control keeps the analysis valid when devices, software, or layout change, and comparison with the alternative route under IEC 62061 helps teams already familiar with safety integrity levels.

Performance Level Scale

Performance LevelProbability of Dangerous Failure per HourTypical Architecture
PL a1e-5 to 1e-4Single channel basic solution
PL b3e-6 to 1e-5Single channel with reliable components
PL c1e-6 to 3e-6Single channel with monitoring
PL d1e-7 to 1e-6Dual channel with diagnostic coverage
PL e1e-8 to 1e-7Dual channel, high coverage and reliability

Real-World Examples

  • Emergency stop at PL d — Dual channel devices, a safety relay with EDM, and category 3 architecture meet the required band with margin.
  • Light curtain at PL c — A Type 4 device with single channel monitoring covers a low severity, easily avoided hazard.
  • Two hand control on a press — Category 3 dual channel logic with synchronism check protects against one hand being freed.
  • Safe speed monitoring on a robot — Safe encoder inputs, a safety controller, and safe torque off together achieve the required level.

📝Hierarchy First

No safety device fixes a hazard that good design could eliminate. Reduce risk by design before adding guards, devices, or procedures.

Common Mistakes

Starting with a device instead of a hazard

Fix: Begin with limits, hazards, and risk estimates so the required performance level is justified, not guessed.

Treating category alone as sufficient

Fix: A category without component reliability, diagnostics, and common cause measures does not achieve a level.

Skipping validation records

Fix: Analysis and test records are required evidence, not optional paperwork.

Key Takeaways

  • Risk assessment defines limits, hazards, and required performance.
  • Risk reduction follows design, then safeguards, then information.
  • Performance level combines architecture, reliability, and diagnostics.
  • Validation with fault injection proves the function and documents it.

Frequently Asked Questions

What is the difference between PL and SIL

Performance levels run from a to e under ISO 13849, safety integrity levels run from 1 to 3 under IEC 62061, and the bands correspond at the low and high ends.

What does category 3 mean

A single fault does not lead to loss of the safety function, and the fault accumulates only if it remains undetected between checks.

Why is common cause failure scored separately

Redundant channels can fail together from shared causes, so diversity, separation, and environmental measures must be assessed explicitly.

Interview Questions

Q1: How do you determine the required performance level

Estimate risk from severity, exposure, and avoidance after initial design measures, evaluate it against the table, and assign the required PL for each safety function.

Q2: Walk through proving a safety function meets its target

Confirm the category, gather component MTTF data, compute diagnostic coverage, score common cause failure, calculate the probability per hour, then validate by analysis and test.


Extended Learning: Beyond the Basics

Key Concepts Summary

This lesson covers fundamental concepts that serve as building blocks for more advanced topics. Master these basics before moving to intermediate and advanced material.

Prerequisite Knowledge

Before studying this topic in depth, ensure you understand:

  • Basic definitions and terminology
  • Core formulas and their derivations
  • Common applications in real-world scenarios
  • Typical pitfalls and misconceptions

Step-by-Step Walkthrough

Let us work through a complete example to solidify understanding:

Step 1: Identify the problem type. Determine which category this problem falls into and which approach is most appropriate.

Step 2: Apply the relevant formula. Substitute known values into the appropriate equation, paying attention to units and constraints.

Step 3: Simplify and solve. Work through the algebra step by step, checking each intermediate result.

Step 4: Verify the answer. Check that the solution satisfies the original conditions and makes logical sense.

Common Mistakes to Avoid

  1. Misidentifying the problem type — Always start by categorizing the problem
  2. Incorrect formula application — Verify the formula applies to your specific case
  3. Unit errors — Always check units are consistent throughout
  4. Sign errors — Pay careful attention to positive and negative values
  5. Rounding too early — Keep full precision until the final answer
  6. Forgetting constraints — Check that solutions satisfy all given conditions

Real-World Applications

Understanding this concept is essential for:

  • Advanced problem solving in examinations
  • Building intuition for more complex topics
  • Developing analytical thinking skills
  • Applying mathematical reasoning to practical situations

Practice Exercises

  1. Basic: Solve 5 problems of increasing difficulty using the core concept.
  2. Intermediate: Apply the concept to word problems with multiple steps.
  3. Advanced: Combine this concept with 2-3 other topics in a comprehensive problem.
  4. Challenge: Create your own problem that requires this concept plus additional knowledge.

Interview and Exam Tips

  • Common question patterns: Identify which exam or interview formats test this topic
  • Time management: Practice completing problems within time constraints
  • Common traps: Know the typical mistakes examiners set as distractors
  • Verification strategy: Develop a quick method to check your answer

Related Topics

Quick Reference Card

ConceptFormula/RuleKey InsightCommon Use
Core DefinitionSee main textUnderstand the intuitionFoundation for all applications
Key FormulaSee main textMemorize the derivationDirect problem solving
Special CaseSee main textRecognize when it appliesSimplifies complex problems
Edge CaseSee main textKnow the limitationsAvoids errors

Further Reading

For students who want to go deeper:

  • Standard textbooks on the subject
  • Research papers applying this concept
  • Online courses with video explanations
  • Practice problem collections with detailed solutions
CW

ChatWhole Learn Editorial Team

Written by experienced data scientists, software engineers, and educators. All content is reviewed by industry professionals to ensure accuracy and relevance.

Last reviewed: 2026-11-14

—
☆☆☆☆☆
0 ratings

Rate & Feedback

Need Expert Industrial Automation & PLC Help?

Get personalized tutoring, project support, or professional consulting.

Advertisement